LOCK

Syntax
Remarks
Example

MATH

Syntax
reference frequency to the measured value.
Related Commands: LFREQ
10 OUTPUT 722; "LINE?"
20 ENTER 722;A
30 PRINT A
40 END
Lockout. Enables or disables the multimeter's keyboard
LOCK [control]
control
The control parameter choices are:
Numeric
control
Query
Parameter
Equiv.
OFF
0
ON
1
Power-on control = OFF.
Default control = ON.
The LOCK command is accessible from the front panel's alphabetic command
directory. However, executing the LOCK command from the front panel has no
effect.
After disabling the keyboard, you can only enable it from the controller or by
cycling power. The LOCK command disables the multimeter's Local key.
Query Command. The LOCK? query command returns the present LOCK
mode. Refer to "Query Commands" near the front of this chapter for more
information.
Related Commands: LOCAL LOCKOUT (GPIB command)
OUTPUT 722;"LOCK ON" !DISABLES THE KEYBOARD
The MATH command enables or disables real-time math operations.
MATH [operation_a][,operation_b]
!MEASURES THE LINE FREQUENCY
!ENTERS RESPONSE INTO COMPUTER'S A VARIABLE
!PRINTS RESPONSE
Description
Enables the keyboard (normal operation)
Disables the keyboard (pressing keys has no affect)
Chapter 6 Command Reference

LOCK