Error messages
ADU error messages
Introduction to ADU error messages
This section contains a complete alphabetical list of all ADU
error messages for ADU version 7.85.16.0 and earlier.
IMPORTANT:
apply to the server you are troubleshooting. Refer to the server documentation for information
on procedures, hardware options, software tools, and operating systems supported by the
server.
WARNING:
information in the server documentation before removing, replacing, reseating, or modifying
system components.
Accelerator Board not Detected
Description: Array controller did not detect a configured array accelerator board.
Action: Install an array accelerator board on an array controller. If an array accelerator board is
installed, check for proper seating on the array controller board.
Accelerator Error Log
Description: List of the last 32 parity errors on transfers to or from the memory on the array accelerator
board. Displays starting memory address, transfer count, and operation (read and write).
Action: If many parity errors are listed, you may need to replace the array accelerator board.
Accelerator Parity Read Errors: X
Description: Number of times that read memory parity errors were detected during transfers from memory
on the array accelerator board.
Action: If many parity errors occurred, you may need to replace the array accelerator board.
Accelerator Parity Write Errors: X
Description: Number of times that write memory parity errors were detected during transfers to memory on
the array accelerator board.
Action: If many parity errors occurred, you may need to replace the array accelerator board.