Mirror Data Miscompare; No Configuration For Array Accelerator Board - HP ProLiant BL620c - G7 Server Troubleshooting Manual

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

Logical Drive X Status = Recovering (rebuilding data on a replaced drive)
Description: A physical drive in this logical drive has failed and has now been replaced. The replaced
drive is rebuilding from the mirror drive or the parity data.
Action: No action is required. Normal operations can occur; however, performance will be less than
optimal until after the rebuild process completes.
Logical Drive X Status = Wrong Drive Replaced
Description: A physical drive in this logical drive has failed. The incorrect drive was replaced.
Action:
Power down the server.
1.
Replace the drive that was incorrectly replaced.
2.
Replace the original drive that failed with a new drive.
3.
CAUTION:
Loose Cable Detected - Logical Drives May Be Marked FAILED Until Corrected
Description: At power up, the system does not detect a configured physical drive or an external storage
unit that was previously detected before the last system shutdown. This event can occur if the user removes
one or more drives after the system is powered down or if a loose cable or malfunction prevents the
drives from spinning up.
Action: If a drive or enclosure has been removed or disconnected, do the following:
Power down the server.
1.
Check cabling.
2.
Power up the server and storage enclosure at the same time.
3.
If drives are failed or purposely removed while the system is off:
Reboot the server.
1.
When prompted during POST, press F2 to fail the missing drives.
2.

Mirror Data Miscompare

Description: Data was found at reset initialization in the posted-write memory; however, the mirror data
compare test failed resulting in that data being marked as invalid. Data loss is possible.
Action: Replace the array accelerator board.

No Configuration for Array Accelerator Board

Description: The array accelerator board has not been configured.
Action: If the array accelerator board is present, run ACU
configure the board.
Do not run the server setup utility and try to reconfigure, or data will be lost.
("Array Configuration
Utility" on page 70) to
Error messages 101