Power Management Module Error Codes - HP ProLiant BL620c - G7 Server Troubleshooting Manual

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info).
Interconnect Module B (10-Connector) Error Code
LED code: 16-1 or 16-2
Location: Interconnect module - side B (10-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
Press the server blade management module reset button.
1.
Reseat the interconnect module.
2.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info).
Replace the interconnect module.
3.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info).
Interconnect Module B (6-Connector) Error Code
LED code: 18-1 or 18-2
Location: Interconnect module - side B (6-connector)
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
Press the server blade management module reset button.
1.
Reseat the interconnect module.
2.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info).
Replace the interconnect module.
3.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP
website (http://www.hp.com/products/servers/proliant-bl/p-class/info).
Unknown server blade management module error code
LED code: 19-1
Location: Unknown
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
Press the server blade management module reset button.
1.
Replace the server blade management module.
2.

Power management module error codes

Power supply error codes
Location
Power Supply - Slot 1
LED codes
1-1 or 1-2
Error messages 164