Audible Beeps: None
Possible Cause: Real-time clock system battery has lost power. The system will lose its configuration every
time AC power is removed (when the system is unplugged from AC power source) and this message
displays again if a battery failure has occurred. However, the system will function and retain
configuration settings if the system is connected to the AC power source.
Action: Replace battery (or add external battery).
1610-Temperature Violation Detected. - Waiting 5 Minutes for System to Cool
...Press Esc key to resume booting without waiting for the system to cool.
WARNING: Pressing Esc is NOT recommended as the system may shutdown unexpectedly.
Audible Beeps: None
Possible Cause: The temperature measured by one of the system temperature sensors has exceeded
acceptable levels. In many cases, this is due to the ambient inlet air temperature exceeding acceptable
levels.
Action: Be sure to follow all of the environmental requirements for the server.
Space and airflow
Always allow adequate ventilation.
o
Always populate the racks with blanking panels and the enclosures with blade blanks.
o
Always populate the server with air baffles, blanks, and heatsinks.
o
Always operate the server with the access panel installed.
o
Temperature
Only operate the server in a room where the temperature does not exceed the recommended
temperature for the server.
For more information about the optimum environment for the server, see the server user guide on the HP
website (http://www.hp.com/support).
1611-CPU Zone Fan Assembly Failure Detected. Either...
...the Assembly is not installed or multiple fans have failed in the CPU zone.
Audible Beeps: None
Possible Cause: Required fans are missing or not spinning.
Action:
Check the fans to be sure they are installed and working.
1.
Be sure the assembly is properly connected and each fan is properly seated.
2.
If the problem persists, replace the failed fans.
3.
If a known working replacement fan is not spinning, replace the assembly.
4.
1611-CPU Zone Fan Assembly Failure Detected. Single fan...
...failure. Assembly will provide adequate cooling.
Error messages 135