MSG_CPU_RR_2

Event type: A Pentium floating point bug exists.
Action: Replace the processor.

MSG_CPU_RR_3

Event type: Coprocessor geometric series is out of range.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.

MSG_CPU_RR_5

Event type: Refresh count is out of range.
Action: Replace the board that contains the memory controller.

MSG_CPU_RR_6

Event type: Unable to perform arithmetic operations on registers.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.

MSG_CPU_RR_7

Event type: CPU speed is out of range.
Action: Replace the processor.