HP ProLiant BL620c - G7 Server Troubleshooting Manual page 140

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

Audible Beeps: None
Possible Cause: This configuration is not recommended because of controller memory requirements.
Action: Perform RAID migration to lower stripe size using the Array Configuration Utility (on page 70).
1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but
Array Accelerator size <= 32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 0 or 1, reducing the number
of drives in the array, or upgrading the Array Accelerator module.
Audible Beeps: None
Possible Cause: Upgrade the Array Accelerator module to a larger size.
Action: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot X Drive Array Controller - Redundant ROM Reprogramming Failure
...Replace the controller if this error persists after restarting system.
Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detects a checksum failure, but is unable to
reprogram the backup ROM.
Action:
Update the controller to the latest firmware version
1.
If the problem persists, replace the controller.
2.
1714-Slot X Drive Array Controller - Redundant ROM Reprogramming Failure
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation is interrupted by a power cycle, or flash ROM is failing. The
controller detects a ROM checksum error and automatically switches to the backup ROM image.
Action: If this backup ROM image is a lower version than the originally running image, update the
controller to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps: None
Possible Cause: The memory is beginning to fail.
Action: If this error persists, replace the controller.
1716-Slot X Drive Array Controller - Unrecoverable Media Errors Detected on
Drives
...Errors will be fixed automatically when these sectors are overwritten. Backup and restore recommended.
("Firmware
maintenance" on page 80).
Error messages 140

Advertisement

Table of Contents
loading

This manual is also suitable for:

ProliantProliant 100 series

Table of Contents