Audible Beeps: None
Possible Cause: This configuration is not recommended because of controller memory requirements.
Action: Perform RAID migration to lower stripe size using the Array Configuration Utility (on page 70).
1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but
Array Accelerator size <= 32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 0 or 1, reducing the number
of drives in the array, or upgrading the Array Accelerator module.
Audible Beeps: None
Possible Cause: Upgrade the Array Accelerator module to a larger size.
Action: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot X Drive Array Controller - Redundant ROM Reprogramming Failure
...Replace the controller if this error persists after restarting system.
Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detects a checksum failure, but is unable to
reprogram the backup ROM.
Action:
Update the controller to the latest firmware version
1.
If the problem persists, replace the controller.
2.
1714-Slot X Drive Array Controller - Redundant ROM Reprogramming Failure
...Backup ROM has automatically been activated. Check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation is interrupted by a power cycle, or flash ROM is failing. The
controller detects a ROM checksum error and automatically switches to the backup ROM image.
Action: If this backup ROM image is a lower version than the originally running image, update the
controller to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred
...Warning: Corrected Memory Error(s) were detected during controller memory self-test...
Audible Beeps: None
Possible Cause: The memory is beginning to fail.
Action: If this error persists, replace the controller.
1716-Slot X Drive Array Controller - Unrecoverable Media Errors Detected on
Drives
...Errors will be fixed automatically when these sectors are overwritten. Backup and restore recommended.
("Firmware
maintenance" on page 80).
Error messages 140