1737-Slot X Drive Array - Redundant Cabling Configuration has excess Device
Paths...
...Redundant I/O paths to some devices attached to the controller are exceeding per device limit by firmware.
These excess paths are ignored.
Audible Beeps: None
Possible Cause: The redundant cabling configuration creates more redundant I/O paths than the firmware
allows.
Action: Update the firmware to the correct version. Verify the redundant cabling configuration.
1738-Slot X Drive Array - Storage Enclosure Redundant Cabling Problem Detected
...Check storage box I/O module and cable to restore redundant paths to the following disk drive(s):
Select "F1" to post this message on reboots if problem persists
Select "F2" to disable this message on reboots if problem persists with logical drive(s) corresponding to these disk
drives
Audible Beeps: None
Possible Cause: A problem exists with the storage enclosure redundant cabling. A single path was found
to drives that were previously connected redundantly.
Action:
Check the storage box I/O module and cable to restore redundant paths to the drives, then do one of the
following:
If the redundant cables/paths were not purposefully removed, press F1 to display this message on
reboot until the problem is resolved. The drives should be accessible through the remaining path.
If the redundant paths were purposefully removed, press F2 to disable this message on all
subsequent reboots.
1739-Slot X Drive Array - Redundant Cabling Configuration is not as
recommended...
...Refer to product user guide.
Audible Beeps: None
Possible Cause: Incorrect redundant cabling configuration
Action: For information on how to cable the device in a supported manner for dual-domain redundant
path support, see the product user guide.
1742-Slot X Drive Array - Previously Ejected Drive(s) Detected...
Select "F1" to continue ignoring these physical drives.
Select "F2" to add these physical & logical drive(s) to this controller.
Error messages 145