Audible Beeps: None
Possible Cause: A media error is detected on a drive and cannot be corrected because of degraded fault
tolerance or a media error at the same location on another drive in the same array. An unrecoverable
read error is returned to the operating system when this block address is read.
Action: Backup and restore the data on the drive. Sequential write operations to the affected blocks
should resolve the media errors.
1717-Slot X Drive Array Controller - Disk Drive(s) Reporting OVERHEATED
Condition
Audible Beeps: None
Possible Cause: The drives listed in this message are currently in an overheated state.
Action: Check the fans and be sure the air flows over the drive. Install the access panel, if removed.
1718-Slot X Drive Array Controller - Device discovery found more devices attached
to this controller than firmware currently supports...
...Some devices are ignored.
Audible Beeps: None
Possible Cause: The firmware does not support the number of devices currently attached to the controller.
Action:
If release notes indicate that support for additional devices has been added, upgrade to the latest
version of controller firmware.
Remove some of the devices attached to the controller.
1719-Slot X Drive Array - A controller failure event occurred prior to this power-up
(previous lock-up code = 0x####)
Audible Beeps: None
Possible Cause: A controller failure event occurred before the server powered up.
Action: Install the latest version of controller firmware. If the condition persists, then replace the controller.
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI:
Port Y: SCSI ID Z.
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action:
If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in
the array are online.
Error messages 141