209-Mirror Memory Configuration - Memory Sizes on boards X and Y do not
match
Audible Beeps: 1 long, 1 short
Possible Cause: The overall size of two boards participating in a mirrored configuration does not match.
Action: Install or reinstall DIMMs to support mirrored mode.
209-RAID Memory Configuration - Memory Sizes on boards X and Y do not match
Audible Beeps: 1 long, 1 short
Possible Cause: The overall size of two boards participating in a RAID does not match.
Action: Install or reinstall DIMMs to support RAID mode.
210-Memory Board Power Fault on board X
Audible Beeps: 1 long, 1 short
Possible Cause: A problem exists with a memory board powering up properly.
Action: Exchange DIMMs and retest. Replace the memory board if problem persists.
210-Memory Board Failure on board X
Audible Beeps: 1 long, 1 short
Possible Cause: A problem exists with a memory board powering up properly.
Action: Exchange DIMMs and retest. Replace the memory board if problem persists.
212-Processor Failed, Processor X
Audible Beeps: 1 short
Possible Cause: Processor in slot X failed.
Action: Run Insight Diagnostics
indicated.
214-Processor PPM Failed, Module X
Audible Beeps: None
Possible Cause: Indicated PPM failed.
Action: Run Insight Diagnostics
indicated.
("HP Insight
Diagnostics" on page 75) and replace failed components as
("HP Insight
Diagnostics" on page 75) and replace failed components as
Error messages 131