WARNING - Drive Write Cache is Enabled on X
Description: Drive has its internal write cache enabled. The drive may be a third-party drive, or the
operating parameters of the drive may have been altered. Condition can cause data corruption if power
to the drive is interrupted.
Action: Replace the drive with a supported drive or restore the operating parameter of the drive.
WARNING - Mixed Feature Processors Were Detected
Description: Mixed feature processors were detected. The server will boot using the lowest featured
processor.
If you install supported processors with different features in the same system, this informational message is
displayed.
WARNING - Resetting Corrupted CMOS
Description: This informational message displays when the ROM detects that CMOS is corrupted. The
default values are restored. This message does not display if a user has intentionally invalidated the
configuration through RBSU by erasing NVRAM.
WARNING - Resetting Corrupted NVRAM
Description: This informational message displays when the ROM detects that NVRAM is corrupted. The
default values are restored. This message does not display if a user has intentionally invalidated the
configuration through RBSU by erasing NVRAM.
WARNING - Resetting Corrupted System Environment
Description: This informational message is displayed when the System Environment Variables are
corrupted. The default values are restored. This message does not display if a user has intentionally
invalidated the configuration through RBSU by erasing NVRAM.
WARNING - Restoring Default Configurations as Requested
Description: If, on the subsequent power up, you select the option to erase NVRAM in RBSU, this
informational message is displayed.
WARNING: Storage Enclosure on SCSI Bus X Indicated it is Operating in Single
Ended Mode...
...SOLUTION: This usually occurs when a single-ended drive type is inserted into an enclosure with other drive
types; and that makes the entire enclosure operate in single ended mode. To maximize performance replace the
single-ended drive with a type that matches the other drives.
Description: One or more single-ended mode SCSI drives are installed in an external storage unit that
operates in LVD mode.
Action: The array continues to operate, but installing all LVD drives maximizes performance.
Error messages 110