Advertisement

180-Log Reinitialized
Audible Beeps: None
Possible Cause: The IML
corruption of the log.
Action: Event message, no action is required.

200 Series

201-Memory Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics
indicated.
203-Memory Address Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics
indicated.
207 - Invalid Memory Configuration Detected. DIMMs installed when no
corresponding processor is detected.
Description: Processor is required to be installed for memory to be used.
Action: Populate the processor socket or remove the DIMM.
207-Invalid Memory Configuration - DIMMs must be installed in pairs or
sequentially
Audible beeps: 1 long, 1 short
Possible cause: The system is configured with only one FBDIMM and the system does not support single
FBDIMM mode, or multiple FBDIMMs are installed but were not installed in the proper order.
Action: Do one of the following:
Install a valid FBDIMM pair if the system does not support single channel memory mode.
Remove and install FBDIMMs in the proper order.
207-Invalid Memory Configuration - DIMMs Must be Installed Sequentially
Audible Beeps: 1 long, 1 short
Possible Cause: Installed DIMMs are not sequentially ordered.
Action: Reinstall DIMMs in proper order.
("Integrated Management
("HP Insight
Diagnostics" on page 75) and replace failed components as
("HP Insight
Diagnostics" on page 75) and replace failed components as
Log" on page 76) has been reinitialized due to
Error messages 128