HP ProLiant BL620c - G7 Server Troubleshooting Manual page 114

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

Logical drive state: The logical drive is queued for erase.
Action: No action is required. Logical drive migrate and extend operations are not possible while the
erase operation is in progress.
Logical drive state: The logical drive is queued for expansion.
Action: No action is required.
Logical drive state: The logical drive is queued for rebuilding.
Action: No action is required. Normal operations can occur; however, performance will be less than
optimal during the rebuild process.
Logical drive state: This logical drive has a high physical drive count...
...as well as a high stripe size value such that a controller lock up could occur. It is recommended that the stripe size
be migrated to a lower value.
Action: Migrate the stripe size to a lower value using the Array Configuration Utility (on page 70).
NVRAM Error: Board ID could not be read...
...(Read-Only Table failed checksum test). Unrecoverable error.
Action: Contact HP support
NVRAM Error: Bootstrap NVRAM image failed checksum test,...
...but a backup image was found and successfully restored. A system restart is needed.
Action: Restart the server.
NVRAM Error: Bootstrap NVRAM image failed checksum test...
...and could not be restored. This error may or may not be recoverable. A firmware update might be able to correct
the error.
Action: Update the controller firmware. If the update fails, contact HP support
173).
Physical Drive State: The data on the physical drive is being rebuilt.
Action: No action is required. Normal operations can occur; however, performance will be less than
optimal during the rebuild process.
Physical Drive State: This drive is not supported for configuration...
...and should be disconnected from this controller.
Action: Replace the physical drive with a drive supported by the controller.
Redundancy State: This controller has been setup to be part of a redundant pair of
controllers....
...but redundancy is temporarily disabled. Redundancy is temporarily disabled because capacity expansion,
extension, or migration is in progress. Redundancy will be enabled when this process is complete.
("Contacting
HP" on page 173).
("Contacting
HP" on page
Error messages 114