Power Supply Solution Not Fully Redundant; Processor X Unsupported Wattage - HP ProLiant BL620c - G7 Server Troubleshooting Manual

Proliant g4/5/6 servers
Hide thumbs Also See for ProLiant BL620c - G7 Server:
Table of Contents

Advertisement

Power Supply Solution Not Fully Redundant

Audible beeps: None
Possible cause: The minimum power supply requirement is installed, but a redundant power supply is
missing or failed.
Action: Do one of the following:
Install a power supply.
Replace failed power supplies to complete redundancy.

Processor X Unsupported Wattage.

Audible beeps: 1 long, 1 short
Possible cause: Processor not supported by current server.
Action: Refer to the server documentation for supported processors. If the processor is supported, remove
the processor, update the system to latest ROM, and then reinstall the processor.
Redundant ROM Detected - This system contains a valid backup system ROM.
Audible Beeps: None
Possible Cause: The system recognizes both the system ROM and redundant ROM as valid. This is not an
error.
Action: None
REDUNDANT ROM ERROR: Backup ROM Invalid. - ...
...run ROMPAQ to correct error condition.
Audible Beeps: None
Possible Cause: The backup system ROM is corrupted. The primary ROM is valid.
Action: Run ROMPaq Utility to flash the system so that the primary and backup ROMs are valid.
REDUNDANT ROM ERROR: Bootblock Invalid. - ...
...contact HP Representative.
Audible Beeps: None
Possible Cause: ROM bootblock is corrupt.
Action: Contact an authorized service provider.
REDUNDANT ROM ERROR: Primary ROM invalid. Booting Backup ROM. -...
...run ROMPAQ to correct error condition
Audible Beeps: None
Possible Cause: The primary system ROM is corrupt. The system is booting from the redundant ROM.
Action: Run ROMPaq Utility to restore the system ROM to the correct version.