3. Slide the drive slowly into the hot swap bay until it stops. See Figure 4-4.
CAUTION
Be careful not to damage the light pipes as you insert the
drive. They are very fragile.
You must insert the drive slowly and gently . If the drive is
inserted too quickly when the system is on, in-rush current
can cause the power supply to shut down.
4. Press the ejector handle in until you feel the latch click into place. Closing
the ejector handle engages the drive with the electrical connector in the
hot-swap mass storage cage and seats the drive.
5. If the drive is unseated in the cage after closing the ejector handle, the
handle was probably not pulled out far enough, and the locking latch
failed to engage the hot-swap mass storage cage. Repeat from step 2.
Figure 4-4. Installing a Drive in the HP NetServer LPr
Installing Mass Storage Devices
29