Prevent Rack Tip-Over, Equipment Damage, And Injury; Tools Required; Installation Basics - HP D5970A - NetServer - LCII Installation Manual

Hp netserver lpr installation guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 9
Prevent Rack Tip-Over, Equipment Damage,
and Injury
WARNING
To prevent the rack from tipping over, extend the anti-tip foot
from under the front and/or rear of the enclosure prior to
mounting any components. Also lower the leveler feet at the
four corners of the rack to improve stability and prevent the
rack from rolling away as devices are inserted into their rack
mounts. Failure to use the anti-tip foot and leveler feet could
result in serious injury.
CAUTION
The HP NetServer weighs approximately 38 lb. (17.5 kg).
Take appropriate lifting precautions. Get help from another
person when loading the LPr towards the top of a rack.

Tools Required

To install the HP NetServer LPr in a rack, you need a T25 Torx driver.

Installation Basics

Always keep the following safety and environmental issues in mind, especially if
you install the HP NetServer in a non-HP rack environment:
Begin installing components at the bottom of the rack.
Once the component is correctly secured in the rack, add the front
panel (bezel) to the unit. See Chapter 3 for details.
Maximum Recommended Ambient Temperature. The maximum
recommended ambient temperature of the room is 35 C (95 F).
Elevated Operating Ambient Temperature. The ambient operating
temperature within a closed or multi-unit rack assembly may exceed the
room's ambient temperature. Make sure that the temperature within the
rack itself does not exceed 35 C (95 F).
62
Mounting the Server in the Rack

Advertisement

Table of Contents
loading

Table of Contents