NETGEAR GSM7252PS - ProSafe 52 Ports Gigabit Ethernet L2 Managed Stackable Switch User Manual page 521

Prosafe gigabit l3 managed switch web management user manual
Hide thumbs Also See for GSM7252PS - ProSafe 52 Ports Gigabit Ethernet L2 Managed Stackable Switch:
Table of Contents

Advertisement

ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual
1.
User ID identifies the name of the user.
2.
Use User Name to enter the name of the user. Name can contain 1 to 31 alphanumeric
characters. User names once created cannot be changed/modified.
3.
Set Edit Password to "Enable" only when you want to change the password. The default
value is "Disable".
4.
Use Password to enter a password for the user. The password length can be from 8 to 64
characters.
5.
Use Confirm Password to enter the password for the user again.
6.
Use Group to assign the user to at least one User Group. To assign a user to more than
one group, press the Ctrl key and click each group. New users are assigned to the 1-Default
user group by default.
7.
Use Session Timeout to enter the number of seconds a user is permitted to remain
connected to the network. Once the Session Timeout value is reached, the user is logged
out automatically. A value of 0 means that the user does not have a Session Timeout limit.
The valid range is 0 to 86400 seconds and the default value is 0.
8.
Use Idle Timeout to enable Logout once idle time-out is reached (seconds). If the attribute
is 0 or not present then use the value configured for the captive portal.
9.
Use Max Bandwidth Down to specify the maximum rate (Rate in bits per seconds) at which
a client can receive data from the network. 0 indicates use global configuration (Range: 0 –
536870911 bps.)
10.
Use Max Bandwidth Up to specify the maximum rate (Rate in bits per seconds) at which a
client can send data into the network. 0 indicates to use the global limit (Range: 0 –
536870911 bps.)
11.
Use Max Output to specify the number of octets the user is allowed to transmit. After this
limit has been reached the user will be disconnected. 0 indicates to use the global limit
(Range: 0 – 4294967295.)
12.
Use Max Input to specify the number of octets the user is allowed to receive. After this limit
has been reached the user will be disconnected. 0 indicates to use the global limit (Range:
0 – 4294967295.)
13.
Use Max Total to specify the number of bytes the user is allowed to transmit and receive.
The maximum number of octets is the sum of octets transmitted and received. After this limit
has been reached the user will be disconnected. 0 indicates to use the global limit (Range:
0 – 4294967295.)
Chapter 6. Managing Device Security
| 521

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsm7228psProsafe gsm7352s

Table of Contents