NETGEAR GSM7252PS - ProSafe 52 Ports Gigabit Ethernet L2 Managed Stackable Switch User Manual page 239

Prosafe gigabit l3 managed switch web management user manual
Hide thumbs Also See for GSM7252PS - ProSafe 52 Ports Gigabit Ethernet L2 Managed Stackable Switch:
Table of Contents

Advertisement

ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual
IPv6 Statistics
Table 16.
Field
Total Datagrams Received
Received Datagrams Locally Delivered
Received Datagrams Discarded Due To Header
Errors
Received Datagrams Discarded Due To MTU
Received Datagrams Discarded Due To No Route
Received Datagrams With Unknown Protocol
Received Datagrams Discarded Due To Invalid
Address
Received Datagrams Discarded Due To Truncated
Data
Received Datagrams Discarded Other
Description
The total number of input datagrams received by the
interface, including those received in error.
The total number of datagrams successfully
delivered to IPv6 user-protocols (including ICMP).
This counter is incremented at the interface to which
these datagrams were addressed which might not be
necessarily the input interface for some of the
datagrams.
The number of input datagrams discarded due to
errors in their IPv6 headers, including version
number mismatch, other format errors, hop count
exceeded, errors discovered in processing their IPv6
options, etc.
The number of input datagrams that could not be
forwarded because their size exceeded the link MTU
of outgoing interface.
The number of input datagrams discarded because
no route could be found to transmit them to their
destination.
The number of locally-addressed datagrams
received successfully but discarded because of an
unknown or unsupported protocol. This counter is
incremented at the interface to which these
datagrams were addressed which might not be
necessarily the input interface for some of the
datagrams.
The number of input datagrams discarded because
the IPv6 address in their IPv6 header's destination
field was not a valid address to be received at this
entity. This count includes invalid addresses, e.g.,
::0, and unsupported addresses, e.g., addresses with
unallocated prefixes. For entities which are not IPv6
routers and therefore do not forward datagrams, this
counter includes datagrams discarded because the
destination address was not a local address.
The number of input datagrams discarded because
datagram frame didn't carry enough data.
The number of input IPv6 datagrams for which no
problems were encountered to prevent their
continued processing, but which were discarded
(e.g., for lack of buffer space). Note that this counter
does not include any datagrams discarded while
awaiting re-assembly.
Chapter 4. Routing
| 239

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsm7228psProsafe gsm7352s

Table of Contents