ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual
1.
Use Interface to select the interface for which data is to be configured or displayed.
2.
Use Admin Mode to set the administrative status of MLD on the selected interface. The
default value is disable.
3.
Use Version to enter the version to be configured on the selected interface. Valid values
are(1 to 2). The default value is 2.
4.
Use Query Interval to enter the frequency in seconds at which MLD host-query packets are
to be transmitted on this interface. Valid values are from 1 to 1800. The default value is 125.
5.
Use Query Max Response Time to enter the maximum query response time to be
advertised in MLDv2 queries on this interface, in milliseconds. Valid values are from 0 to
65535. The default value is 10000 milliseconds.
6.
Use Robustness to specify the robustness parameter for the selected interface. This
variable allows tuning for the expected packet loss on a subnet. If a subnet is expected to be
lossy, the robustness variable may be increased. MLD is robust to (robustness variable-1)
packet losses.
7.
Use Startup Query Interval to specify the value that indicates the configured interval (in
seconds) between General Queries sent by a Querier on startup.
8.
Use Startup Query Count to specify the value that indicates the configured number of
Queries sent out on startup, separated by the Startup Query Interval.
9.
Use Last Member Query Interval to enter the last member query interval in milliseconds.
This is the maximum response time to be inserted into group-specific queries sent in
response to leave group messages, and is also the amount of time between group-specific
query messages. Valid values are from 0 to 65535. The default value is 1000 milliseconds.
10.
Use Last Member Query Count to enter the number of queries to be sent on receiving a
leave group report. Valid values are from 1 to 20. The default value is 2.
Table 76.
Field
Operational Mode
Description
The operational status of MLD on the Interface.
Chapter 4. Routing