3. Enter a name from one to 64 characters in length. All characters in the ISO
Latin-1 character set, excluding control characters, are allowed.
4. Select one of the following options from the drop-down list under the Name field:
Rx Throughput. An alert will occur if the threshold set for receive
throughput is reached.
Tx Throughput. An alert will occur if the threshold set for transmit
throughput is reached.
Rx or Tx Throughput. An alert will occur if the threshold set for either
receive or transmit throughput is reached.
5. Click Next. A new screen displays with additional parameters. The name
configured for the alert displays at the top of the screen. Click Previous to return
to the previous screen, as shown in
Figure 2–41: New Threshold Alerts dialog box—second screen
6. Enter a percentage from 1 through 100 for % utilization. When throughput
reaches this percentage of port capacity, a threshold alert will occur.
7. Enter the amount of cumulative minutes in which the % utilization should exist
during the notification interval before an alert is generated. You can also select At
any time if you want an alert to occur whenever the set % utilization is reached.
The valid range is 1 to the interval set in step 8 (following).
8. Enter the interval in minutes in which throughput is measured and threshold
notifications can occur. The valid range is 5 minutes to 70,560 minutes.
edge switch 2/24 installation guide
Installing and Configuring the Edge Switch 2/24