Tandberg Data STORAGELOADER Installation And User Manual page 85

Compact tape cartridge loader
Hide thumbs Also See for STORAGELOADER:
Table of Contents

Advertisement

Tandberg Data
1209
Failed to fetch at
slot 09
2000
Drive not found
2001
Drive hardware
fault detected.
StorageLoader Installation and User Manual
Failed to eject
1. Reboot the loader and retry the
cartridge from
operation.
drive
2. Try to eject the cartridge from
the drive via the front panel menu.
3.Remove the drive FRU. Connect
power to drive and push the
drive's eject button. If this fails,
remove cartidge by following the
drive's emergency eject
procedure.
Communication
1. Reboot the loader and retry the
error between
operation.
the loader and
2. Remove back-panel cover plate
the drive.
and check the SCSI cabling and
the ADI cabling.
The drive has
Reboot the loader and retry the
reported a
operation. If the problem persists
hardware fault.
replace the drive.
Maintenance
Defect drive or
robotics. Defect
cartridge.
SCSI and signal
cables, power
cables; defective
power supply;
defective drive.
Defective drive
83