Tandberg Data
flashes in addit ion t o t he Am ber LED
being lit . The program m ing operat ion
takes less than one minute.
9. When reprogram m ing is com plet ed, t he
loader will do a normal reboot
I f t he firm ware upgrade operat ion failes during point 8 due t o a
power shut- down or similar, the loader may require service.
To verify t hat t he FW version in t he loader is correct , ent er t he
view dat a m enu. Select t he " Aut oloader I nfo" and from t here t he
"Loader Firmware Revision" entry to see the revision number.
6.2.2 Possible Upgrade Problems
I f a power loss or a failure occurs during code download and ECC
Checking, t he original FW m ay be int act . I t is possible t o rest art
t he FW upgrade procedure. However, if t he failure occurs during
flash erase or program m ing, t he firm ware will be corrupt ed and a
special procedure m ust be used t o load a new code. Cont act your
Technical Support Representative for assistance.
6.3 Embedded Diagnostics
The StorageLoader includes two levels of diagnostics:
The Power- On Self Test (POST) — Performs several
verification and memory tests when you power on the unit.
User Diagnostics — Selectable from the front panel
6.4 Reinstalling the Transport Lock
Before
St orageLoader
shipped over a dist ance,
t he t ransport lock m ust
be
inst alled.
t ransport
lock
prevent dam age t o t he
robotics during transport
and handling.
Note: Dam age t o t he
robot ics during shipping
will not be covered by
warranty
unless
t ransport
lock
58
t he
is
The
will
t he
Figure 6.1 Transport lock marked with
is
red plastic tab
StorageLoader Installation and User Manual
Maintenance
Need help?
Do you have a question about the STORAGELOADER and is the answer not in the manual?
Questions and answers