Verifying Npv Traffic Management - Cisco N5010P-N2K-BE Software Configuration Manual

Nx-os software configuration guide
Table of Contents

Advertisement

Chapter 34
Configuring N Port Virtualization
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
To display a list of devices on a server interface and their assigned NP uplinks, enter the show npv
flogi-table command on the Cisco Nexus 5000 Series switch:
switch# show npv flogi-table
--------------------------------------------------------------------------------
SERVER
INTERFACE VSAN FCID
--------------------------------------------------------------------------------
vfc3/1
vfc3/1
vfc3/1
vfc3/1
Total number of flogi = 4
For each server interface, the External Interface value displays the assigned NP uplink.
Note
To display the status of the server interfaces and the NP uplink interfaces, enter the show npv status
command:
switch# show npv status
npiv is enabled
External Interfaces:
====================
Interface: fc2/1, VSAN: 1, FCID: 0x1c0000, State: Up
Interface: fc2/2, VSAN: 1, FCID: 0x040000, State: Up
Interface: fc2/3, VSAN: 1, FCID: 0x260000, State: Up
Interface: fc2/4, VSAN: 1, FCID: 0x1a0000, State: Up
Number of External Interfaces: 4
Server Interfaces:
==================
Interface: vfc3/1, VSAN: 1, NPIV: No, State: Up
Number of Server Interfaces: 1
To view fcns database entries for NPV edge switches, you must enter the show fcns database command
Note
on the core switch.
To view all the NPV edge switches, enter the show fcns database command on the core switch:
core-switch# show fcns database
For additional details (such as IP addresses, switch names, interface names) about the NPV edge
switches that you see in the show fcns database output, enter the show fcns database detail command
on the core switch:
core-switch# show fcns database detail

Verifying NPV Traffic Management

To display the NPV traffic map, enter the show npv traffic-map command.
NPV Traffic Map Information:
OL-16597-01
PORT NAME
1
0xee0008 10:00:00:00:c9:60:e4:9a 20:00:00:00:c9:60:e4:9a fc2/1
1
0xee0009 20:00:00:00:0a:00:00:01 20:00:00:00:c9:60:e4:9a fc2/2
1
0xee000a 20:00:00:00:0a:00:00:02 20:00:00:00:c9:60:e4:9a fc2/3
1
0xee000b 33:33:33:33:33:33:33:33 20:00:00:00:c9:60:e4:9a fc2/4
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
Verifying NPV
EXTERNAL
NODE NAME
INTERFACE
34-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 5000 series