Sample Syslog Alert Notification In Full-Text Format - Cisco N5010P-N2K-BE Software Configuration Manual

Nx-os software configuration guide
Table of Contents

Advertisement

Additional References
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Table 26-7
Inserted Fields for an Inventory Event Message (continued)
Data Item
Description
(Plain Text and XML)
(Plain Text and XML)
FRU name
Name of the affected FRU that is generating the event
message.
FRU s/n
Serial number of the FRU.
FRU part number
Part number of the FRU.
FRU slot
Slot number of the FRU.
FRU hardware
Hardware version of the FRU.
version
FRU software version Software version(s) that is running on the FRU.
Table 26-8
Table 26-8
Inserted Fields for a User-Generated Test Message
Data Item
Description
(Plain Text and XML)
(Plain Text and XML)
Process ID
Unique process ID.
Process state
State of process (for example, running or halted).
Process exception
Exception or reason code.

Sample syslog Alert Notification in Full-Text Format

This sample shows the full-text format for a syslog port alert-group notification:
source:MDS9000
Switch Priority:7
Device Id:WS-C6509@C@FG@07120011
Customer Id:Example.com
Contract Id:123
Site Id:San Jose
Server Id:WS-C6509@C@FG@07120011
Time of Event:2004-10-08T11:10:44
Message Name:SYSLOG_ALERT
Message Type:Syslog
Severity Level:2
System Name:10.76.100.177
Contact Name:User Name
Contact Email:admin@yourcompany.com
Contact Phone:+1 408 555-1212
Street Address:#1234 Picaboo Street, Any city, Any state, 12345
Event Description:2006 Oct
Interface e2/5, vlan 1 is up
syslog_facility:PORT
start chassis information:
Affected Chassis:WS-C6509
Affected Chassis Serial Number:FG@07120011
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
26-18
describes the user-generated test message format for full text or XML.
8 11:10:44 10.76.100.177 %PORT-5-IF_TRUNK_UP: %$VLAN 1%$
Chapter 26
Configuring Smart Call Home
XML Tag
(XML Only)
/aml/body/fru/name
/aml/body/fru/serialNo
/aml/body/fru/partNo
/aml/body/fru/slot
/aml/body/fru/hwVersion
/aml/body/fru/swVersion
XML Tag
(XML Only)
/aml/body/process/id
/aml/body/process/processState
/aml/body/process/exception