Configuring Domain Parameters
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m

Persistent FC ID Configuration Guidelines

When the persistent FC ID feature is enabled, you can enter the persistent FC ID submode and add static
or dynamic entries in the FC ID database. By default, all added entries are static. Persistent FC IDs are
configured on a per-VSAN basis.
When manually configuring a persistent FC ID, follow these requirements:

Configuring Persistent FC IDs

To configure persistent FC IDs, perform this task:
Command
Step 1
switch# configuration terminal
switch(config)#
Step 2
switch(config)# fcdomain fcid database
switch(config-fcid-db)#
Step 3
switch(config-fcid-db)# vsan vsan-id wwn
33:e8:00:05:30:00:16:df fcid fcid
switch(config-fcid-db)# vsan vsan-id wwn
11:22:11:22:33:44:33:44 fcid fcid dynamic
switch(config-fcid-db)# vsan vsan-id wwn
11:22:11:22:33:44:33:44 fcid fcid area
OL-16597-01
Ensure that the persistent FC ID feature is enabled in the required VSAN.
Ensure that the required VSAN is an active VSAN. Persistent FC IDs can only be configured on
active VSANs.
Verify that the domain part of the FC ID is the same as the runtime domain ID in the required VSAN.
If the software detects a domain mismatch, the command is rejected.
Verify that the port field of the FC ID is 0 (zero) when configuring an area.
Purpose
Enters configuration mode.
Enters FC ID database configuration submode.
Configures a device WWN
(33:e8:00:05:30:00:16:df) with the FC ID
0x070128 in the specified VSAN.
To avoid assigning a duplicate FC ID, use
Note
the show fcdomain address-allocation
vsan command to display the FC IDs in
use.
Configures a device WWN
(11:22:11:22:33:44:33:44) with the FC ID
0x070123 in the specified VSAN in dynamic
mode.
Configures a device WWN
(11:22:11:22:33:44:33:44) with the FC IDs
0x070100 through 0x701FF in the specified
VSAN.
To secure the entire area for this
Note
fcdomain, assign 00 as the last two
characters of the FC ID.
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide