8.1. ASSIGNMENT OF CONTROL BOARD TERMINALS
1
BCL1+
Not used
2
BCL1-
Not used
3
BLC2+
Not used
4
BCL2-
Not used
5
DI1
Pass Control A
6
DI2
Pass Control B
7
DI3
FCA (NO)
8
DI4
FCB (NO)
9
REL1+
Green Ori Pict A
10
REL1-
11
REL2+
Red Ori Picto A
12
REL2-
13
DI5
Alarm (NO)
(= Out of Service)
14
DI6
15
DI7
16
DI8
17
DI9
18
DI10
Evacuation (NC)
19
DI11
20
DI12
Ctrl Panel A1
21
DI13
Ctrl Panel A2
22
DI14
Ctrl Panel B1
23
DI15
Ctrl Panel B2
24
DI16
Ctrl Panel Key (NO)
25
DI17
Connected to 24V
26
DO7
Green Fct Picto A
27
DO9
Heater
regulated
28
DO10
Electro A
29
DO11
Electro B
30
DO12
LED Lighting
31
AO1
Used (=AI2) (*)
32
AI1
The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using this information for any purpose
other than the use of the products or the execution of the project to which it refers and from communicating it to third parties without prior written agreement of Automatic
Systems. The document is subject to change without notice.
TRS373-MT-EN-01
The table below indicates the factory settings for inputs/outputs.
The output parameters can be changed in the OUTPUT FUNCTION group.
Inputs/outputs for options have been highlighted.
C
BLC3+
BCL3-
BCL4+
BCL4-
24V
24V
24V
24V
REL3+
REL3-
REL4+
REL4-
24V
24V
24V
DI18
24V
24V
24V
24V
24V
24V
24V
24V
24V
DO8
not
self-
24V
DO13
DO14
DO15
AO2
AI2
B
Not used
Not used
Not used
Not used
Green Ori Pict B
Red Ori B Red
Red Fct Picto A
LED Lighting
Green Fct Picto B
Red Fct Picto B
Used
Light sensor
A
24V
PWR
0V
PWR
PE
(PE)
GND
GND
GND
GND
REL5+
Contact Pass A
REL5-
REL6+
Contact Pass B
REL6-
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND