7-4
Code / Range
Message / Explanation
7D01-7DFF
Bad stroke
The optic switch is obscured
too early during the suction
stage, due to high
dispensing pressure along
the circuit.
7E01-7EFF
Error in command
timeout
(Only for simultaneous
circuit)
The CBMaster does not
receive any answer from the
board mounted on the SAPS
7F01-7FFF
Status error on pumping
group
The last two digits of the error codes regarding the SAPS indicate the number of the SAPS involved
in the error condition, in hexadecimal format.
Check that
colorant has
Check that the
NO
NO
not spilled on
dispensing
the optic
nozzle is clean
switch
YES
YES
Check that the
Check value of
power supply
NO
fuses F4 and
cable is
F5 (4A) on
connected to
CBMB
the board
YES
Replace the
board
mounted on
the SAPS
indicated by
the error code
YES
Actions
Remove the
Check pipes
NO
NO
check valve
and replace in
and try to
case of dried
dispense
colorant
YES
YES
Check that the
communication
cable is
NO
connected to
the board
mounted on
the SAPS
YES
YES
NO
Replace
SAPS
YES
COROB™ AUTOMATIC DISPENSERS
From
CorobTECH,
NO
Replace
reduce
SAPS
dispensing
speed
YES
YES
Replace the
board
NO
mounted on
the SAPS
indicated by
the error code
YES

Advertisement