finish refilling the canister, by pouring at least 1 liter of colorant.
–
3.
From CorobTECH, send the command to expand all the bellows pumps of the machine: use the Reset or
the Bellows > Down command.
4.
Repeat Bellows > Up and Bellows > Down commands at least 3 times.
During this operation:
- double check that all the colorants are filling the pipes and flowing out of the nozzle
- double check the absence of leaking in FEDV area
5.
Dispense at least 200 ml from each canister to remove the water/solvent that may be present inside the
canister.
6.
Remember to update the actual colorant level in CorobTECH:
7.
To help the colorant release the emulsified air increase the stirring frequency, then leave the colorant
degas for 8-12 hours.
Version 1.0 - rev0 - May 2006