The drill head must be stationary when taking readings using
Max Mode. If the drill head is moving, data readings will not be
accurate.
You will typically use Max Mode in areas where interference is
high. In areas of high interference, it will be harder to obtain
stable readings. Never rely on unstable depth or data. Max
Mode is not a substitute for prudent operator judgment.
STEP 2 OF 4
At the Locate Mode screen,
hold the trigger for longer
than five seconds to enter
Max Mode.
STEP 3 OF 4
Continue holding the trigger until depth and data stabilize.
If the Max Mode timer fills up before depth and data stabilize, move to a
different location near the drill head and hold to restart.
The timer bar will fill as data is confirmed.