STEP 1 OF 5
Stuff You Should Know
Use standard Height-Above-Ground (HAG) to set a height measurement on
the locator so you don't have to put it on the ground for a depth reading.
Raising the locator above the ground also provides separation from
underground interference that might otherwise reduce the transmitter's
range or cause variable readings.
If you are using TrakStand HAG, see "Turn on Height Above Ground" in the
During Drilling chapter.
HAG must be turned on manually each time after the locator is
powered on or calibrated.
STEP 2 OF 5
To measure for standard HAG, hold the locator at your side as if you were
holding a suitcase.
Measure the distance between the ground and the bottom of the locator
using a tape measure.
STEP 3 OF 5
From the Main menu, select
HAG.
STEP 4 OF 5
Select Set HAG.