Parameter List

Parameters Exclusive to the DATAGET Command
Judgment value parameters
Parameter
Judgment value
Parameters Common to the DATASET/DATAGET Commands
Parameters at image adjustment
Sensitivity adjustment
Parameter
Mode selection
MULTI/HS MULTI
HIGH
MULTI/HS MULTI
LOW
MULTI STEP
AUTO HIGH
AUTO LOW
FIXED
HS MULTI max.
number of
lightings
*1:
The SEARCH command must be executed to enable the HS MULTI sensitivity setting.
176
Serial Communication
Unit No.
Parameter No.
47+10* (task-1)
40
Unit No.
Parameter No.
1
2
1
5
1
6
1
4
1
7
1
8
1
9
1
10
Output Range
0: Error, 1: LOW, 2: PASS,
3: HIGH
Setting range
0: MULTI, 1: AUTO, 2: FIXED, 3:
HS MULTI sensitivity(*1)
1 to 440
1 to 440
0: Fine adjusting, 1: Normal,
2: Rough adjustment
1 to 440
1 to 440
0 to 440 (0: laser out)
2 to 10
ZG2 User's Manual