I/O Circuit Diagrams - Omron ZG2 Series User Manual

Smart sensor 2d profile measuring sensors
Hide thumbs Also See for ZG2 Series:
Table of Contents

Advertisement

I/O Circuit Diagrams

Important
Make sure that the load connected to the "analog output wire (co-axial) - analog GND wire"
satisfies the rating of the set state (voltage or current output) before turning the Controller ON.
Otherwise, the Controller may be damaged.
NPN type (ZG2-WDC11)
Voltage/Current
switch
130
Using the Controller I/O Cable
Brown
Red
Green
Black
Pink
Gray
Blue
Yellow
Light blue
Yellow green
Yellow/black
Purple LD-OFF
White ZERO-RESET
Orange TRIG
White/black
Current output
4 to 20 mA
Co-axial (black)
40 Ω
Voltage output
±10 V
Shielded
24VDC
Load
ALL-PASS
Load
NG
Load
ERROR
Load
ENABLE
GATE
GND (0 V)
BANK A
BANK B
BANK C
BANK D
RESET
Analog output
Current output: 300 Ω max.
Load
Voltage output: 10 kΩ min.
Analog GND
Load
24 VDC