When gang-mounting devices
The following explains how to mount Controllers when using a Data Storage Unit as well
or when gang-mounting two Controllers on the DIN track.
4 4
3
ZG2 User's Manual
1
2
Controller
Link Unit
(sold separately)
5 5
3
1
Hook the connector end of the
Controller onto the DIN track.
2
Push the Controller down onto
the DIN track until the hook on the
I/O cable side is locked.
3
Open the gang-mount cover.
Slide the cover downwards to
remove.
4
Insert the Controller Link Unit into
the connector on the unit on the
left side.
Important
Indentation
The connector must be inserted at the
correct orientation. Insert so that the
indentation on the Controller Link Unit
in the figure above matches the
connector protrusion on the unit on the
left side.