Mounting and Connecting Devices

Mounting the Sensor Head

Never look into the laser beam. Doing so continuously will result in
visual impairment.
Never look into the laser beam.
Do not attempt to dismantle, pressurize, or incinerate the product. Doing so
may cause the laser beam to leak, resulting in the danger of visual
impairment. Do not attempt to dismantle, pressurize, or incinerate the product.
Installations to Suit Measurement Target and Environment
Pay attention to the following points when mounting the Sensor Head to prevent
measurement precision from dropping.
Color/shiny surface boundary
Emission
axis
Boundary line
Narrow grooves or indentations
Measuring stepped objects
ZG2 User's Manual
Mounting near walls
Measurement errors can be reduced by installing the Sensor Head
with the line formed by the emission and reception axes parallel to
the wall, and painting the wall with non-reflective black paint.
Reception
axis
Rotating objects
You can minimize the influence caused by vibration of the rotating object
and positional shifts by installing the Sensor Head with the line formed
by the emission and reception axes parallel to the axis of rotation.
Effect of peripheral lighting
Do not install the Sensor Head in a place where strong light hits the
laser emitter/receiver section of the Sensor. Also, if a measurement
target has a shiny surface, the light from the lighting will be reflected
and a malfunction may occur. In such as case, prevent reflection, for
example, by covering the light to stop reflection.