Omron ZG2 Series User Manual page 191

Smart sensor 2d profile measuring sensors
Hide thumbs Also See for ZG2 Series:
Table of Contents

Advertisement

Measurement timing charts
Mutual interference prevention function: OFF
CH2
CH1
ENABLE signal
ON
(output from CH2)
OFF
PASS/NG signal
(output from CH2)
ON
GATE signal
(output from CH2)
OFF
Mutual interference prevention function: ON
CH2
CH1
ON
ENABLE signal
(output from CH2)
OFF
PASS/NG signal
(output from CH2)
ON
GATE signal
(output from CH2)
OFF
188
Required Settings
TRIG (input to CH2)
Lighting
Lighting
TRIG (input to CH2)
Lighting
Measurement
Measurement
processing
Measurement processing
Measurement cycle
processing
Lighting
Measurement cycle
Integration
processing
Integration
processing
Measurement
processing
ZG2 User's Manual