Note
Hint for adjusting the measurement region
Adjust the start and end points of the region for each measurement point.
2-pt step
P1
P2
(step=P2-P1)
(reference)
Note
Custom settings available for step measurement
Setting value
REGION
MGNIFY
POINT (enabled only in
EXP menu)
76
Setting Measurement Conditions
TRIMMING
↑↓
10.000 mm
←→
123 LINE SET
MEAS/2PTS-1
1ITEM 2CUSTOM
3SCALE
P1
P3
(reference) (reference)
Description
Fine-adjusts the measurement region when it is not ideally
set by AUTO.
Magnifies the profile display.
Sets in more detail which height in the line beam that the
target is to be measured at.
Settings: AVE, PEAK, BTM
2
Enclose the desired
measurement area.
In the EXP menu, select [AUTO] and
set up this item.
Important
Adjust the region so that the center line
is aligned with the "mid point between
the top and bottom of the step."
Center line
3
Check that the region is set
correctly.
When the region is not ideally set to
the desired measurement position,
select
[CUSTOM]-[REGION]
adjust
the
measurement point.
3-pt step
(step=P3-(P1+P2)÷2)
P2
to
region
for
each
Reference
p.87
p.89