Assignments and Functions of I/O Signal Wires

Assignment of output signal wires
Function
Judgment
output
Trigger auxiliary ENABLE
Analog output
128
Using the Controller I/O Cable
Signal
Description
ALL-PASS
Turns ON when the judgment result of all tasks is OK (or
all tasks are not registered).
NG
Turns ON when there is even one task whose judgment
result is NG.
ERROR
Turns ON when there is even one task for which a
measurement error occurred.
Turns ON when trigger input is enabled during trigger
measurement. Turns OFF during bank switching.
Trigger
Continuous
GATE
Turns ON when the measurement result is being fixed.
(The startup and output times can also be set.)
ANALOGOUT/
Connect the analog output wire to an external ammeter or
ANALOGGND
voltmeter, and convert the measurement value for output
as 4 to 20 mA analog current or -10 to +10 V analog
voltage. With analog output, output values can be scaled
or corrected to suit the conditions of the connected
external device.
Note
The maximum response in analog output is 500 µs.
Regular During trigger measurement
OFF
ON
-
ON
Analog Output Settings p.132
Bank switching in progress
OFF
OFF
ZG2 User's Manual