Sysmac cs/cj/one nsj series programmable controllers
Table of Contents

Advertisement

Network Instructions
Operand Specifications
1076
D: First word of received message
Specifies the first word of the received message (D to D+267 max.).
15
D
Contains the number of bytes of received service data from
words D+1 on. Does not include the 2 bytes in word D itself.
Includes only the number of bytes of Service Data starting at
D+1. (If the first or last word contains just one byte of data, the
empty byte in that word is not counted.)
15
D+1
to
D+267
Contains the response's service data (data
following the service code). The byte-order of
this data is specified in bits 12 to 15 of C+1.
Can contain up to 534 bytes (267 words) of
data.
C: First control word
Specifies the first of four control words (C to C+3).
15
C
Set the maximum number of words of data in the received data beginning at D.
The allowed setting range is 0 to 010C hex (268 words).
If the number of words of received data exceeds the value set here, a FINS
error will occur (response too long, code 11 0B) and no data at all will be stored
(in the area starting at D+3).
If the number of words of received data is less than the value set here, the
remaining words (in the area starting at D+3) will be left unchanged.
15
12
11
C+1
Byte order of service data (frame data) stored in areas beginning at S+6 and D+3
0 hex: Stored from leftmost byte (Left
8 hex: Stored from rightmost byte (Right
15
C+2
15
C+3
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Service Data
0
8
7
0
FINS unit address of relaying Communications Unit.
CPU Bus Unit: 10 to 1F hex (unit number + 10 hex)
Special I/O Unit: 20 to 7F hex (unit number + 20 hex)
Port number of the communications port (logical port) for the network
instruction: 0 to 7 hex (F hex: Automatic allocation)
Right
Left
Left
0
Response monitoring time
0001 to FFFF hex (0.1 to 6553.5 s)
0000 hex: 2 s (default setting)
0
Explicit message format
0000 hex: DeviceNet (same as using the 2801 FINS
command)
S
CIO 0000 to
CIO 0000 to
CIO 6140
CIO 6143
W000 to W508
W000 to W511
H000 to H508
H000 to H511
A000 to A956
A000 to A959
T0000 to T4092
T0000 to T4095
Section 3-25
0
0
Right ...)
Right
Left ...)
D
C
CIO 0000 to
CIO 6140
W000 to W508
H000 to H508
A000 to A956
T0000 to T4092