Interrupt Feeding

9-3

Interrupt Feeding

9-3-1

Outline of Operation

Moving by a specified amount in the
direction of travel
Target speed
Speed
Speed
Initial
control
speed
9-3-2

Procedure for Memory Operation

1,2,3...
This section describes the interrupt feeding operation and the data needed for
performing it.
Interrupt feeding is a positioning operation that moves the axis by a specified
amount from the position at which the external interrupt signal was input,
either in the same direction as the direction of travel or in the opposite direc-
tion. It can be started from either from memory operation or from direct opera-
tion. The present position will be set to "0" if an interrupt input signal is input
when the origin is not fixed.
Interrupt input
signal
Position control
(movement by
a specified
amount)
Deceleration
Note
There will be no acceleration or deceleration if there is a reversal as a result of
an interrupt input signal for a movement opposite to the direction of travel.
The initial speed when operation is started using memory operation is deter-
mined by the settings in the sequence data. The initial speed when operation
is started using direct operation is determined by the settings in the axis
parameters.
With memory operation, the positioning sequence completion code is set to
interrupt feeding (5 or 6) and then this sequence number is started and the
interrupt input signal is awaited.
1. Set the positioning sequence completion code to 5 (interrupt feeding in di-
rection of travel) or 6 (interrupt feeding in opposite direction) and write it to
the PCU.
2. In the positioning sequence, set the speed data number and acceleration/
deceleration time number, and set the amount of movement for the inter-
rupt feeding in the position with the same number as the positioning se-
quence. The sign for the position will then become the pulse direction for
speed control. The direction will become CW if it is positive and CCW if it
is negative.
3. Execute START or INDEPENDENT START for the sequence number set
in (1) above.
4. When an interrupt signal is input externally, interrupt feeding will be execut-
ed.
Moving by a specified amount in the
opposite direction
Target speed
Speed
Speed
Initial
control
speed
CW
position
Deceleration
Section 9-3
Interrupt input signal
CW
position
Position control
(movement by a
specified amount)
239