Memory Operation Procedure; Setting Data For Memory Operation; Beginning Words Of Memory Areas - Omron CJ1W-C113 - REV 02-2008 Operation Manual

Position control units
Table of Contents

Advertisement

Memory Operation Procedure

8-2

Memory Operation Procedure

1,2,3...
8-3

Setting Data for Memory Operation

8-3-1

Beginning Words of Memory Areas

202
The procedures for setting data for memory operation are explained below
using the X axis as an example.
1. Set the common parameters. (Refer to 4-3 Common Parameter Area.)
m:
Set the operating data area either to DM or to EM.
m+1:
Set the beginning word of the operating data area (I).
m+2:
Designate the axis parameters.
2. Power up again or restart.
The data in the common parameter area set in (1) above is enabled.
3. Transfer the data. (Refer to SECTION 5 Transferring and Saving Data.)
Transfer the data set for the common parameters and for the axes to the
PCU.
4. Execute START.
Set the sequence number for beginning operation (word n+16, bits 00 to
15).
Turn ON the Sequence Number Enable Bit (word n, bit 00).
Turn START (word n, bit 01) or INDEPENDENT START (word n, bit 02)
from OFF to ON.
The operations in (1) and (2) above are required when using a PCU for the
first time, or when modifying the data in the common parameter area.
The procedure given in step 4 is also used to start sequence number 0.
A simple explanation of the axis parameter area and operating memory area
settings that are used when executing memory operation is given below.
For setting methods and other details, refer to 4-4 Axis Parameter Area and 4-
5 Operating Memory Area.
The beginning words of the operating memory area, operating data area, and
common parameter area used for a Position Control Unit (PCU) are deter-
mined (or set) according to the following.
• Beginning word of the operating memory area, n = CIO 2000 + 10 × unit
number
• Beginning word of the common parameter area, m = D20000 + 100 × unit
number
• Beginning word of the operating data area, l, is specified in m and m+1.
Set the beginning words of the operating data area and designate the axis
parameters used with the common parameters as shown below.
Word
m
Operating data area designation
m+1
Beginning word of operating data area
m+2
Axis parameter designation
Name
Section 8-2
Bit
Reference
00 to 15
SECTION 4
00 to 15
00 to 15

Hide quick links: