SIS Configuration and Control

The DTP2 CrossPoint 82 switchers can be configured and controlled via SIS commands when connected to a
host computer or other device (such as a control system). Attach the host device to the rear panel RS-232
connector or LAN connector, or to the front panel USB port. Commands can be entered using a Telnet application
such as the Extron DataViewer, available at
The default protocol for the RS-232 connection is 9600 baud, 8 data bits, 1 stop bit, no parity, and no flow control.
This section describes SIS communication and control. Topics in this section include:

Host and Switcher Communication

SIS Overview
Command and Response Tables for SIS Commands
Host and Switcher Communication
SIS commands consist of one or more characters per field. No special characters are required to begin or end a
command sequence. When the switcher determines that a command is valid, it executes the command and
sends a response to the host device. All responses from the switcher to the host end with a carriage return and a
line feed
(CR/LF = ] ), indicating the end of the response character string (one or more characters).

Copyright Messages

The copyright message is displayed upon connecting to a switcher via USB, Telnet, SIS via SSH or after a power
cycle via RS-232, and depends on the switcher model.
] (c) Copyright YYYY, Extron Electronics, DTP2 CrossPoint 82 <model>, Vn.nn, 60-1812-0n ]
Ddd, DDD MMM YYYY HH:MM:SS ] (day, date, and time as in Mon, 09 Dec 2019 11:27:33)
YYYY is the year.
<model>, if applicable, is IPCP SA or IPCP MA 70
60-1812- nn is the model part number:
DTP2 CrossPoint 82 base model — 60-1812-01
DTP2 CrossPoint 82 IPCP SA — 60-1812-02
DTP2 CrossPoint 82 IPCP MA 70 — 60-1812-03
V n.nn is the firmware version number.

Password Messages

If the DTP2 CrossPoint 82 is protected by a password, the following password message prompts you for the
password to access the switcher features.
] Password ]
The prompt requires a password, followed by a carriage return. The prompt is repeated if the correct password is
not entered.
For initial setup: On the rear panel of the DTP2 CrossPoint 82, a label is attached containing the following:
The factory-configured passwords for all accounts on this device have been set to the device serial
number. Passwords are case-sensitive.
www.extron.com