Type
Activation
Use
Using an Extron Tweeker or other small
Factory
screwdriver, press and hold in the
Firmware
recessed Reset button for 30 seconds
while applying power to the switcher.
NOTE:
After a factory firmware
reset, update the device with
the latest firmware version. DO
NOT operate with the firmware
version that results from this
mode reset. This temporarily
resets the device to factory
default until power is recycled.
To use factory default firmware,
re-upload that version.
Reset
Press and hold down the Reset button
Network
until the Reset LED blinks two times (at
Settings
6 seconds). Then, press Reset
momentarily (less than 1 second).
Full
Press and hold down the Reset button
Factory
until the Power LED blinks three times
Reset
(approximately 9 seconds). Then,
press Reset momentarily (less than 1
second).

RS-232 and IR Signal Insertion

The twisted pair input and output ports allow you to insert RS-232 and IR control signals onto the same cable that
carries video and audio to extend them to the Over TP port on a connected endpoint (see
page and
figure 32
RS-232 communication can be sent to the far end of the twisted pair connection via a LAN or an AV LAN (IPCP
models only) connector. A control signal applied to a DTP2 CrossPoint 82 LAN port can be routed to the RS-232
port of any connected twisted pair device (see
When connected to an Ethernet LAN, the switcher can be accessed from a computer running a standard Internet
browser. Use a patch or crossover cable to connect the DTP2 CrossPoint 82 device to a computer, control device,
router, or switch.
Reset Mode Summary
Purpose and Results
The device reverts to the factory default firmware.
Use to revert to the factory default version if
incompatibility issues arise with user-loaded
firmware.
Firmware reverts to the factory default for a
power cycle
All user files and settings (drivers, audio and video
adjustments, IP settings, and so on) are maintained.
NOTE:
IP settings revert to factory defaults.
Use to reset all IP settings back to factory defaults:
Port mapping reverts to factory default.
DHCP turns off.
IP address is set to 192.168.254.254.
The Reset LED blinks four times in quick succession
during reset.
The device reverts to the factory defaults except for
firmware.
Use to restart with the default configuration.
All user modifiable configurations reset to default
values including IP settings and real-time
adjustments.
All user loaded files are deleted.
DHCP turns off.
Port mapping reverts to factory default.
The Reset LED blinks four times in quick succession
during the reset.
The initial serial number password is removed and
set to no password.
on page 46). The control signals can be inserted two ways:
DTP2 CrossPoint 82 Scaling Presentation Matrix Switchers • Operation
.
If you do not want to update the firmware
or perform this reset by mistake, cycle power
to the device to return to the firmware version
running prior to the reset.
Ethernet to RS-232 Insertion
SIS Command
Equivalent
(None)
single
E 1ZQQQ }
E ZQQQ }
(Absolute system
reset)
figure 31
on the next
on the next page).