SIS Configuration
and Control
The scaler can be configured and controlled with Extron Simple Instruction Set (SIS)
commands when connected to a host computer or other device (such as a control system).
Attach the host device to the rear panel RS-232 connector or the front panel USB port.
Commands can be entered using a Telnet application such as the Extron DataViewer,
available at
connection uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control. The
protocol cannot be adjusted. This section describes SIS communication and control. Topics
in this section include:

Host and Scaler Communication

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the scaler determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the scaler to the host end with a carriage return and a line feed
(CR/LF =

Scaler-Initiated Messages

When a local event such as a front panel selection or adjustment takes place, the scaler
responds by sending a message to the host. No response is required from the host.
Example scaler-initiated messages are listed here.

Error Responses

When the scaler receives a valid command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command, it returns an error
response tot he host.
E01
E06
E10
E11
E12
www.extron.com
Host and Scaler Communication
SIS Overview
Command and Response Tables
]
), indicating the end of the response character string (one or more characters).
X!
]
X!
(where
is the input number during an input switch).
In
All
]
The scaler sends this response when an input is switched or when a new
Reconfig
signal is detected.
X@]
The scaler sends this response when a hot plug event on output
HplgO
detected.
— Invalid input number
— Invalid switch attempt in this mode
— Invalid command
— Invalid preset number
— Invalid port number
IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control
(see the DataViewer Help file for more details). RS-232
— Invalid parameter
E13
— Not valid for this configuration
E14
— Invalid command for signal type
E17
— Busy
E22
X@