SIS Configuration
and Control
The scaler can be configured and controlled with Extron Simple Instruction Set (SIS)
commands when connected to a host computer or other device (such as a control system).
Attach the host device to the rear panel RS-232 connector or the front panel USB port.
Commands can be entered using a Telnet application such as the Extron DataViewer,
available at
connection uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control. The
protocol cannot be adjusted. This section describes SIS communication and control. Topics
in this section include:
•
•
•
Host and Scaler Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the scaler determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the scaler to the host end with a carriage return and a line feed
(CR/LF =
Scaler-Initiated Messages
When a local event such as a front panel selection or adjustment takes place, the scaler
responds by sending a message to the host. No response is required from the host.
Example scaler-initiated messages are listed here.
•
•
•
www.extron.com
Host and Scaler Communication
SIS Overview
Command and Response Tables
]
), indicating the end of the response character string (one or more characters).
X!
]
X!
(where
is the input number during an input switch).
In
All
]
The scaler sends this response when an input is switched or when a new
Reconfig
signal is detected.
X@]
The scaler sends this response when a hot plug event on output
HplgO
detected.
IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control
(see the DataViewer Help file for more details). RS-232
X@
is
27