Input Wiring Specifications Ce & Rcm - ESAB CUTMASTER 50+ Operating Manual

Plasma cutting system
Table of Contents

Advertisement

2.05
Input Wiring Specifications CE & RCM
3 Phase Input Cable Wiring Requirements
3 Phase Cutmaster 50+ Power Supply Input Cable Wiring Requirements
Input voltage
Volts (V/AC)
3 Phase
400
3 Phase Cutmaster 70+ Power Supply Input Cable Wiring Requirements
Input voltage
Volts (V/AC)
3 Phase
400
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
WARNING
!
!
Protect the circuit with appropriately sized time-delay (slow-blow) fuses and a line-disconnect switch.
0700 402 229
Freq
Power Input
Hz
kVA
50/60
14.2
Freq
Power Input
Hz
kVA
50/60
17.3
INTRODUCTION
CUTMASTER 50+, CUTMASTER 70+
I max
I
eff
Fuse
1
(A)
(A)
(A)
20.4
15.8
25
I max
I
eff
Fuse
1
(A)
(A)
(A)
25
20.4
32
Suggested Sizes
Flexible Cord
(Min. mm
)
2
2.5mm2 (for CE)
4mm2 (for RCM)
Suggested Sizes
Flexible Cord
(Min. mm
)
2
4mm2
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cutmaster 70+

Table of Contents