CUTMASTER 50+, CUTMASTER 70+
Note that 4T trigger mode is only available at plate cutting mode. When grid cutting mode is
selected, 4T trigger mode can't be selected.
70A
150V
3)
GAS PURGE SCREEN
To enter gas purge, press the control knob to enter menu screen. Turn the knob clockwise to enter
gas purge screen.
Press the control knob to active the gas purge, press control knob again to stop the gas purge, rotate
the control knob to exit the gas purge screen.
70A
150V
4)
GAS PRESSURE UINT SELECTION SCREEN
In idle state, set 22A current and select 4T trigger mode. Only when the 4T trigger mode is highlighted,
press the control knob for about 5s to enter the gas pressure unit selection screen. Turn the control
knob, select the gas pressure unit (psi/bar/kPa), and press the control knob to confirm the selection.
22A
0V
40
75
psi
2T
75
psi
2T
Gas purge off
75
psi
4T
70A
150V
70A
150V
Gas purge on
OPERATION
75
psi
4T
75
psi
2T