Voltage divider
RAW ARC VOLTAGE
Voltage divider
The 4 position DIP switch, P1, makes available the following divide ratios:
All OFF:
DIV1-1 ON:
DIV1-2 ON:
DIV1-3 ON:
DIV1-4 ON:
Divided arc voltage signal is isolated.
Raw Arc Voltage
Refer to Appendix 4.
NOTE!
Only one position should be on at a time.
Rating:
The OK to Move are relay contacts rated for maximum of 30V AC or DC at 1 amp maximum.
Start SW input requires a switch or relay contact rated for at least 24VDC at 5mA.
0700 402 229
= 20:1 for ESAB (Default for RCM);
= 30:1;
= 40:1 for Inova;
= 50:1 for IHT, SC3000&3100, Hypertherm® (Default for ETL & CE);
= 80:1 for TD iHC
INSTALLATION
CUTMASTER 50+, CUTMASTER 70+
DIP switch (4 position)