Input Wiring Specifications - ESAB Cutmaster 60 Operating Manual

Hide thumbs Also See for Cutmaster 60:
Table of Contents

Advertisement

2.05

Input Wiring Specifications

ESAB Cutmaster
Input voltage
Volts
380
3 phase
400
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
I
is taken at rated minimum duty cycle.
1max
I
is taken at 100% rated duty cycle.
1eff
Manual 0-5402
60 Power Supply Input Cable Wiring requirements
®
Freq
Power Input
Hz
kVA
50/60
11
50/60
11
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on US Electric Code and Canadian Electric Code
INTRODUCTION
ESAB CuTmASTEr 60
I
I
Fuse (amps)
1max
1eff
16
11
20
16
11
20
Suggested Sizes
Flexible Cord (Min.
AWG)
14# (around
2.5mm
)
2
14# (around
2.5mm
)
2
2-3