Power Supply Basic Parts Replacement - ESAB CUTMASTER 50+ Operating Manual

Plasma cutting system
Table of Contents

Advertisement

5.05

Power Supply Basic Parts Replacement

Optional Single-Stage Filter Element Replacement
These instructions apply to power supplies where the optional Single-Stage Filter has been installed.
The Power Supply shuts down automatically when the Filter Element becomes completely saturated.
The Filter Element can be removed from its housing, dried, and reused. Allow 24 hours for Element to
dry. Refer to Section 6, Parts List, for replacement filter element catalog number.
1.
Remove power from power supply.
2.
Shut OFF air supply and bleed down system before disassembling Filter to change Filter
Element.
3.
Disconnect gas supply hose.
4.
Turn the Filter Housing Cover counter-clockwise and remove it. The Filter Element is located
inside the Housing.
5.
Remove the Filter Element from the Housing and set Element aside to dry.
6.
Wipe inside of housing clean, then insert the replacement Filter Element open side first.
7.
Replace Housing on Cover.
8.
Reattach gas supply. Check for leaks.
NOTE!
If unit leaks between housing and cover, inspect the O-ring for cuts or other damage.
This completes the parts replacement procedures.
0700 402 229
Housing
Filter
Element
(Cat. No. 9-7741)
Spring
O-ring
(Cat. No. 9-7743)
Cover
Barbed
Fitting
Optional Single-Stage Filter Element Replacement
SERVICE
CUTMASTER 50+, CUTMASTER 70+
Assembled Filter
Art # A-02476
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cutmaster 70+

Table of Contents