Power Supply Specifications Ce; 2.06.01 Additional Power Supply Specifications; Input Wiring Specifications Ce - ESAB CUTMASTER 40 Operating Manual

Plasma cutting system
Hide thumbs Also See for CUTMASTER 40:
Table of Contents

Advertisement

CUTMASTER 40
2.06

Power Supply Specifications CE

Input Power
1 Phase Input Power Cable CE
Output Current
Power Supply Gas Filtering Ability
Inlet Pressure

2.06.01 Additional Power Supply Specifications

Ambient Air Temperature
230 VAC Units
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low or the output voltage (DC) is higher than
shown in this chart.
2.07

Input Wiring Specifications CE

1 Phase Input Cable Wiring Requirements
1 Phase CutMaster 40 Power Supply Input Cable Wiring Requirements
Input voltage
Volts
230 CE
1 Phase
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
18
CM 40 240 VAC 1 Phase Power Supply Specifications
CM 40 Power Supply Duty Cycle *
Duty Cycle*
Current
DC Voltage
Freq
Power Input
Hz
kVA
50
6.0
230 VAC, Single Phase, 50 Hz
Power Supply includes 2.5M single phase 2.5mm² input
cable with Schuko plug
15 - 40 Amps, Continuously Adjustable
Particulates to 5 Microns
90-125 PSI (6.2-8.6 bar / 620-862 Kpa)
Duty Cycle Ratings @ 40° C (104° F)
Operating Range 0° - 50° C
35%
40 Amps
135
I max
I
eff
1
26.1
15.5
INTRODUCTION
Rating
60%
100%
30 Amps
20 Amps
130
135
Suggested Sizes
Fuse
Flexible Cord
(amps)
(Min. AWG)
50
2.5mm2
0-5570

Advertisement

Table of Contents
loading

Table of Contents